Electronics Line iconnect Instrukcja Użytkownika Strona 8

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 33
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 7
2.3: Wiring Diagram
Z4
Z3
Z2
Z1
ZONE
CONNECTIONS
F2 F3
AUX
-
+
KPD
K2 K1
PROTECTION FUSES:
F1 (BATT): 1.6A/250V
F2 (AC): 1.6A/250V
F3 (AUX): 1.0A/250V
F4 (Bell): 1.0A/250V
Electronics Line (E.L.) recommends testing the system at least
once a week. Refer to the testing procedure found in the user
manual.
AUX OUTPUT CURRENT DRAW:
The auxiliary output current allowed for peripheral units must
not exceed 300mA when one keypad is installed. For each
additional keypad (up to 3 max.) the permitted current draw
is reduced by 50mA.
AUXILIARY POWER OUTPUT:
AC Operated: 13.6 - 14.0V
Battery Operated: 12V Nominal
Label Part Number:
ML0024C (2/99)
AC Transformer
50/60Hz
15-16.5Vac
22-30VA
Do not connect to
a switch controlled
receptacle.
LED Keypad
BELL/SIREN OUTPUT:
600mA available for
security applications.
OBSERVE PROPER
WIRING CONNECTIONS
(Refer to the Installation and
Operation Manual for
further information)
1 2 3 4 5 6 7 8 9 10 11 12 14 15 17 18 19 20
Optional
Earth
Connection
PGM
13 16
Telephone Line
Connections
Tamper
Zone
B
L
A
C
K
R
E
D
12V/3.2Ah BATTERY:
Replace the battery every
3 - 5 years.
The maximum charging
current is 350mA.
+
-
JPD Jumper
for factory
default restore
Electronics Line (E.L.) Ltd. - Penta
Household Burglary Alarm Panel
N.C.
2.2K
1
/
4
W
2.2K
1
/
4
W
Typical End
of Line
Resistor
Zone
Connections
(EOLR)
N.C.
F4F1
-
+
Przeglądanie stron 7