3.8: Zone Bypassing/Unbypassing
The Penta offers the user the ability to bypass zones. When a zone is bypassed, it is
ignored by the system and will not generate an alarm when tripped.
To bypass a zone:
1. Press Q, 1.
2. Enter a valid user code; the System LED flashes and the LEDs of any currently
bypassed zones light up.
3. Enter the number of the zone to be bypassed; the corresponding zone LED lights up.
4. Press # to exit bypass mode; the bypassed zones flash.
To unbypass a zone:
1. Press Q, 1.
2. Enter a valid user code; the System LED flashes and the LEDs of any currently
bypassed zones light up.
3. Enter the number of the zone to be unbypassed; the corresponding zone LED turns off.
4. Press # to exit bypass mode.
Note: Disarming the system automatically unbypasses all bypassed zones.
3.9: Event Logs
The event logs record events that the system has undergone since the last arming. If
any events have been recorded in either event log, the System LED flashes until the
relevant event log has been viewed. In the event that a trouble condition still exists, the
System LED continues to flash until the condition has been remedied.
Emergency/Trouble Event Log
Zone tamper, keypad trouble or any of the three distress key alarms are registered in
the Emergency/Trouble event log.
To view the Emergency/Trouble event log:
1. Press Q, 2; the various trouble conditions are indicated by the zone LEDs.
The following is a summary of the trouble condition that each LED indicates when lit:
1 - Tamper or Keypad Trouble 2 - Alarm from P key
3 - Alarm from F key 4 - Alarm from E key
2. Press # to exit the event log.
Note: The event logs can only be viewed when the system is disarmed.
Zone Alarm Event Log
The Zone Alarm event log displays the zones from which an alarm was generated since
the system was last armed.
To view the Zone Alarm event log:
1. Press Q, 3; an alarm from a specific zone is indicated by the corresponding zone
LED.
2. Press # to exit the event log.
Both logs are automatically reset when the system is next armed.